IPC.6.d pe assessor validation records pe pakka grill karega. Requirement: DAILY har load me chemical indicator tape + Class IV strip lagao, aur B-class autoclave pe daily Bowie-Dick test + leak rate test. WEEKLY biological indicator — Geobacillus stearothermophilus spore vial, 24 ghante incubate karke result log karo. Har load ORALZY → Compliance → Sterilisation Log me: load number, content description, time, temperature, pressure, indicator result, operator name. Agar koi indicator FAIL ho jaye → poora load reprocess + autoclave service-call. Recall SOP (IPC.6.e) bhi taiyar ho: har pouch pe autoclave batch no + date; failure ya breakdown pe ICN last successful test ke baad ke saare loads identify karta hai, unhe freeze karta hai, chair-side cabinet se withdraw karta hai, autoclave repair + successful biological indicator ke baad re-sterilise. Agar koi instrument use ho chuka → patient ko notify + HAI ke liye post-procedure surveillance. READY: spore vials stock me, weekly BI log bharaa hua, Bowie-Dick strips saved.
Autoclave ke validation tests kaunse chahiye — Bowie-Dick aur biological indicator kitni baar?
Daily: chemical indicator tape + Class IV strip har load + Bowie-Dick + leak rate. Weekly: biological indicator (spore vial). Har load Sterilisation Log me record.
Where in ORALZY: ORALZY → Compliance → Sterilisation Log + SOP Library → IPC.6.d/e