Diagnosis: Temperature excursion (e.g. LA cartridges, emergency adrenaline, kuch vaccines) potency gira sakta hai. Range NABH me define honi chahiye.
Karo:
- Turant us fridge ke temp-sensitive stock ko 'Do Not Use' tag ke saath quarantine karo.
- Kitni der aur kitna temperature bahar gaya note karo (min/max thermometer se). Manufacturer stability data / pharmacist se poocho ki drug usable hai ya discard.
- NABH Hub → Incidents me ek incident banao aur temperature log/register me excursion entry karo. Discard hua stock stock-register me out karo.
- CAPA: root cause (power cut/fridge fault/door open), corrective (repair + backup arrangement), preventive (temp alarm + daily log + power backup).
Aage se: Fridge me min-max thermometer + alarm, aur daily temperature log schedule. Emergency drug list (NABH Hub → Master Lists → Drug Lists) ke stock ko protect karo.
Edge case: Emergency drugs (adrenaline) agar affected — replace pehle karo, kyunki anaphylaxis ke liye active drug hona critical hai.