Zyada tar clinics lab outsource karte hain — tab AAC-6 ke 8 elements MOU + vendor pe shift ho jate hain. READY rakho: (1) Lab MOU jisme scope (crown/PFM/zirconia/denture/RPD/ortho appliance) + per-work TAT likha ho — single crown 7d, bridge 10d, full denture 14d, ortho appliance 5d; (2) Lab requisition me UHID, dentist name, work type, shade, due-date — ORALZY ka digital requisition auto-fill karta hai; (3) impression dispatch se pehle disinfection + sealed biohazard bag; waste impression material Yellow bag me (BioMedicalWasteLog); (4) remake/correction log — LabOrder me 'remake reason' field har repeat pe bharna hai, monthly remake-rate review quality manager kare. AAC-7 QA ke liye: annual dentist feedback + calibration register (RegistersPage → Calibration) + quarterly dento-prosthetic meeting minutes (doctor + lab technician failed cases review). AAC-8 lab safety sirf in-house lab pe lagta hai — MSDS, PPE, fire extinguisher. Note: SOP me aacInhouseLab token NABH Personnel me set karna hai ('operates' / 'does not operate').
Outsourced dental lab ke liye NABH audit me kya ready rakhna hai?
AAC-6/7/8: Lab MOU (scope + TAT defined), UHID-wali requisition, impression disinfection + BMW disposal, remake log, calibration certs, aur quarterly dento-prosthetic meeting minutes.
Where in ORALZY: Practice → Lab Orders + Lab Portal; MOU: Settings → MOUs → Dental Lab; SOPs: NABH Hub → SOP Library → AAC-6/7/8