Kahan: Patient chart → "Docs" → "Imaging" → "Cephalometric" tab, ya Treatment → Clinical → Specialty → Orthodontics → patient chuno → "Open ceph tracer →". Menu ka Treatment → Imaging → X-rays & Photos → Ceph Analysis wahi tab kholta hai par wahan patient chunne ka box nahi hai, isliye upload par "Please select a patient first" aata hai.
Upload: "Choose ceph X-ray" (patient ka chehra right ki taraf, sirf image, 25 MB tak).
Adjust: dot ko mouse se drag karo, ya "📍 Landmark coords (19)" me row chunkar arrow keys (Shift = 5 px) — har badlav par analysis dobara calculate hota hai. mm values ke liye "🔧 Fine-tune calibration". "Steiner" / "Indian" button se norm table badlo. "👁 Hide tracing" se lines chhupao. "🖨 Print" se A4 report. Purani analyses "Pichli analyses" me.
Abhi ki kami: ceph X-ray image web screen par load nahi hoti (sirf dots aur tables dikhte hain), isliye dots ko asli anatomy par khiskana sambhav nahi — ORALZY support ko batao. Tab tak "Radiographs" tab me X-ray type "cephalometric" se upload karke 8 points (Sella, Nasion, Orbitale, Porion, A, B, Menton, Gonion) lagao aur "Analyze" dabao — SNA, SNB, ANB, FMA, MP-SN milte hain.
Mobile app me Ceph abhi kaam nahi karta (patient ke saath kholne ka raasta nahi) — web use karo.